13 Nov 2026 | By Ron Fellowes MIFSM, GIFireE, CertNCRQ
The Building Safety Act does not apply the same requirements to every building. This guide explains the scope of the Act, the higher-risk building definition, key height thresholds and how requirements differ between occupation, construction and other parts of the legislation.
The Building Safety Act 2022 introduced wide-ranging changes to building safety in England, but not every requirement applies to every building. Some provisions affect the wider built environment, while the most stringent occupation requirements apply specifically to higher-risk buildings.
This article explains the scope of the Building Safety Act, which buildings fall within the higher-risk regime, and when other Building Safety Act requirements may apply.
Does the Building Safety Act 2022 Apply to All Buildings?
The Building Safety Act 2022 does not impose the same requirements on every building.
Which requirements apply depends on factors such as:
- Building height and number of storeys
- How the building is used
- Whether it contains residential units
- Whether it is occupied or under construction
- The type of building work being carried out
- Ownership and repairing responsibilities
The Act also covers different areas, including building control, building regulations, higher-risk buildings and protections relating to certain historical building safety defects.
A residential block below 18 metres, for example, may fall outside the occupied higher-risk building regime but still be affected by other provisions of the Act.
Landlords, building owners and managing agents should identify which requirements apply to each building rather than treating the Act as a single set of rules for all properties.
Which Building Safety Requirements Apply to Your Building?
Different building safety requirements apply depending on a property’s height, number of storeys, use and legal status. The table below summarises the main thresholds for residential buildings in England.
| Building type or threshold | Legislation | What it means |
| Multi-occupied residential buildings with common parts | Regulatory Reform (Fire Safety) Order 2005 | Fire safety duties apply to the relevant common parts, structure, external walls and flat entrance doors. Responsible Persons must assess fire risks and maintain appropriate precautions. |
| Residential buildings with storeys over 11 metres | Fire Safety (England) Regulations 2022 | Additional duties include quarterly checks of communal fire doors and annual checks of flat entrance doors, using best endeavours for the latter. |
| At least 11 metres or five storeys, with at least two dwellings | Building Safety Act 2022 – relevant buildings | Certain leaseholder protections relating to historical building safety defects may apply, subject to the statutory conditions and exclusions. |
| At least 18 metres or seven storeys, with at least two residential units | Building Safety Act 2022 – occupied higher-risk buildings | Additional duties include registration with the Building Safety Regulator, managing building safety risks, maintaining the golden thread, preparing safety case reports and engaging with residents, subject to the statutory criteria and exclusions. |
These thresholds are not interchangeable. A building can fall within several categories, and meeting one threshold does not automatically mean every requirement in another regime applies.
For example, a six-storey residential block measuring 12 metres may be subject to additional fire door inspection duties and fall within the definition of a relevant building for leaseholder protections, without qualifying as a higher-risk building under the occupation regime.
Building height and storeys must be assessed using the measurement rules for the relevant legislation.
What Is the Definition of a Higher-Risk Building?
Under the Building Safety Act 2022, an occupied higher-risk building (HRB) in England generally contains at least two residential units and is at least 18 metres tall or has seven or more storeys, subject to statutory exclusions.
The definition differs during design and construction, when certain hospitals and care homes are also included. Mixed-use buildings can qualify where they meet the relevant criteria.
For a detailed explanation of building types, exclusions and measurement rules, read our guide to higher-risk residential buildings.
Examples of Buildings That May Fall Within the Act
The following examples show how the requirements can differ depending on a building’s height, use and residential accommodation.
| Building example | Does the occupied HRB regime apply? | What else may apply? |
| Eight-storey block of flats with shops on the ground floor | Yes, provided it contains at least two residential units and no statutory exclusion applies. The shops do not automatically exclude it. | Fire Safety Order duties and additional requirements under the Fire Safety (England) Regulations 2022. |
| Five-storey block of flats measuring 14 metres | No, assuming the height and storey count are correctly measured. | Fire Safety Order duties, additional fire door checks and potentially the Building Safety Act’s leaseholder protections. |
| Sheltered housing scheme | Depends. Sheltered housing can qualify if it meets the height or storey threshold and contains at least two residential units. | Fire Safety Order duties and potentially additional fire door requirements, depending on the building. |
| Purpose-built student accommodation block | Depends. Student accommodation can qualify where it meets the statutory height, storey and residential-unit criteria and is not excluded. | Fire Safety Order duties and applicable building control requirements. |
| Care home | No, where the building is used entirely as a care home. | Fire Safety Order duties still apply. Care homes meeting the relevant height or storey threshold can fall within the higher-risk building regime during design and construction. |
These examples are illustrative. Building use, configuration and the statutory measurement rules must be checked before confirming whether a particular property qualifies.
What If You’re Not Sure Whether Your Building Is Higher-Risk?
If a building is close to the threshold or its classification is unclear, check the following before deciding which requirements apply:
- Confirm the building’s height and storey count. Check both against the statutory measurement rules. A building only needs to meet one of the two thresholds.
- Confirm the number of residential units. Establish whether the building contains at least two residential units and whether the occupation criteria are met.
- Check how the building is used. Mixed-use buildings, sheltered housing and student accommodation may require closer assessment.
- Review the statutory exclusions. Certain building uses are excluded from the occupied higher-risk building regime, even where the height or storey threshold is met.
- Seek advice if the classification remains unclear. Consult the government’s guidance on identifying higher-risk buildings or contact the Building Safety Regulator for guidance.
Do not assume a building falls outside the wider Building Safety Act requirements simply because it does not qualify as an occupied higher-risk building.
Need Support Assessing Fire Safety Risks Across Your Residential Portfolio?
Osterna supports housing associations, managing agents and large private landlords with Fire Risk Assessments, fire door inspections and compartmentation surveys across residential buildings.
Our services help you identify fire safety risks, prioritise remedial work and maintain the records needed to demonstrate how risks are being managed.
Does the Building Safety Act Apply to Existing and New Buildings?
Both existing and new buildings can fall within the scope of the Building Safety Act.
Existing occupied HRBs are subject to ongoing requirements covering areas such as registration, building safety risks, the Golden Thread, Safety Case Reports and resident engagement. Refurbishment or remediation work can also trigger building control requirements.
New HRBs are subject to the Building Safety Regulator‘s (BSR) building control regime during design and construction.
The building’s current status and any proposed work therefore need to be considered when establishing which requirements apply.
What Does the Building Safety Act Mean for Landlords and Managing Agents?
Landlords and managing agents need to understand both which requirements apply to a building and who holds the legal responsibility for meeting them.
An Accountable Person (AP) is an individual or organisation that meets the statutory criteria through ownership of, or qualifying legal repairing obligations for, a higher-risk building’s common parts. These include the building’s structure and exterior, subject to specified exceptions, and areas shared by residents of more than one residential unit.
A building may have more than one Accountable Person. Where this happens, a Principal Accountable Person (PAP) is identified under the statutory rules and has additional responsibilities, including registering the building with the Building Safety Regulator.
Managing agents can carry out building safety activities on behalf of landlords and other dutyholders, but managing a property does not automatically make an agent an Accountable Person.
Responsibilities may include arranging inspections, maintaining building safety information, coordinating remedial work and communicating with residents. Management agreements should clearly define who carries out each activity, while landlords and other dutyholders retain appropriate oversight of their legal responsibilities.
Housing associations can read Building Safety Act: What Housing Associations Need to Know for more detail on how these requirements affect social housing portfolios.
How Does Fire Safety Fit Into Building Safety Act Compliance?
The Building Safety Act does not replace existing fire safety responsibilities. Landlords, building owners and managing agents still need to comply with the Regulatory Reform (Fire Safety) Order 2005 where it applies.
In residential buildings, this can require ongoing assessment, inspection and maintenance of the measures used to protect residents from fire. Depending on the building, this may include:
- Fire Risk Assessments to identify fire hazards, assess risk and determine whether existing precautions are appropriate
- Fire door inspections to identify defects that could affect the performance of fire doors
- Compartmentation surveys to assess whether walls, floors and other fire-resisting construction can restrict the spread of fire and smoke
These activities can also provide important information for organisations managing higher-risk buildings, particularly when assessing fire risks, planning remedial work and maintaining accurate building safety records.
Housing associations, landlords and managing agents should make sure findings are reviewed, prioritised and tracked through to completion rather than treating inspections as standalone compliance exercises.
Understanding the Scope of the Building Safety Act
There is no single building type or height threshold that defines the entire Building Safety Act scope.
The 18-metre or seven-storey threshold is central to the higher-risk building regime, but other provisions use different definitions. The building’s use, lifecycle stage, proposed work and legal arrangements can all affect which requirements apply.
Landlords, housing associations, building owners and managing agents should establish the applicable regime for each building rather than assuming that properties outside the HRB definition fall outside the Act altogether.
Osterna supports organisations responsible for residential buildings with Fire Risk Assessments, fire door inspections, compartmentation surveys and wider fire safety compliance.
Speak to the Osterna team about your building safety requirements.
Frequently Asked Questions
It can. A five-storey building will not qualify as a higher-risk building during occupation on storey count alone, as that threshold is seven storeys or 18 metres. However, other parts of the Building Safety Act legislation may still apply.
For example, a building at least five storeys or 11 metres high containing at least two dwellings may meet the definition of a relevant building for certain leaseholder protections, subject to the statutory criteria and exclusions.
The building safety regime continues to place greater emphasis on accountability, competence, building control and evidence that applicable safety standards have been met.
For higher-risk building work, the Building Safety Regulator has an important building control role, with clients, designers and contractors required to meet specific duties. The wider reforms introduced following the Grenfell Tower tragedy are intended to improve how fire and structural safety risks are managed throughout a building’s lifecycle.
Yes, mixed-use buildings can fall within the Building Safety Act. A building containing shops, offices or other commercial premises alongside residential accommodation can still qualify as a higher-risk building where it meets the relevant height, storey and residential-unit criteria.
The building’s overall use and configuration need to be considered rather than assuming commercial areas take it outside the regime.
An Accountable Person is an organisation or individual with specified legal responsibility for the common parts of an occupied higher-risk residential building, based on ownership or repairing obligations.
There can be more than one Accountable Person, with the Principal Accountable Person carrying additional responsibilities. These duties include managing relevant fire and structural safety risks and helping safeguard residents through effective building safety arrangements.
Related articles
-
Emergency Lighting Regulations: A Guide for UK Responsible Persons
Emergency lighting helps occupants evacuate safely when normal lighting fails, but many Responsible Persons are unsure which regulations apply. This guide explains UK emergency lighting legislation, the role of BS 5266, where emergency lighting is required, and how it supports wider fire safety compliance.
Read More about Emergency Lighting Regulations: A Guide for UK Responsible Persons -
Dry Riser Testing Regulations: What Building Owners Need to Know
Dry riser testing is essential for maintaining reliable firefighting systems within residential and commercial buildings. This guide explains the legislation and British Standards governing dry riser inspection and pressure testing, recommended testing frequencies, Responsible Person responsibilities, common defects, and how planned maintenance supports ongoing fire safety compliance.
Read More about Dry Riser Testing Regulations: What Building Owners Need to Know -
How Often Should Emergency Lighting Be Tested?
Emergency lighting testing helps ensure escape routes remain illuminated during a fire or power failure. This guide explains the monthly and annual testing routine required under BS 5266, who’s responsible, and what the law expects from Responsible Persons.
Read More about How Often Should Emergency Lighting Be Tested? -
How Much Does Fire Extinguisher Inspection Cost?
Fire extinguisher inspection costs vary depending on the number of extinguishers, building complexity, servicing requirements, and reporting needs. This guide explains the factors that influence pricing, what’s included within a professional inspection service, and how to obtain an accurate quotation.
Read More about How Much Does Fire Extinguisher Inspection Cost? -
Fire Extinguisher Inspection Checklist: What’s Included
A fire extinguisher inspection helps ensure portable firefighting equipment remains accessible, operational, and ready for use. This guide explains what a fire extinguisher inspection is, what’s included in a typical inspection checklist, and the key checks Responsible Persons should carry out as part of an effective fire safety maintenance programme.
Read More about Fire Extinguisher Inspection Checklist: What’s Included -
A Guide to HMO Fire Risk Assessment Requirements
Many HMO landlords understand they have fire safety responsibilities, but fewer are clear on exactly what the law requires. Misunderstanding those duties can lead to compliance issues, licensing problems, and increased risk to residents. This guide explains the fire risk assessment requirements that apply to HMOs and what landlords and managing agents need to do in practice.
Read More about A Guide to HMO Fire Risk Assessment Requirements -
A Guide to Fire Risk Assessments for Landlords
Not every landlord needs a fire risk assessment, but misunderstanding where the legal duty applies can create significant compliance risks. Discover which properties require an assessment, the legislation involved, and what landlords need to do to meet their fire safety responsibilities.
Read More about A Guide to Fire Risk Assessments for Landlords -
What Is the Difference Between a PCFRA and a PEEP?
A Person-Centred Fire Risk Assessment and a Personal Emergency Evacuation Plan are often confused, but they are designed to achieve different outcomes. This guide explains the key differences, when each is appropriate, and how they work together to support fire safety within residential buildings.
Read More about What Is the Difference Between a PCFRA and a PEEP? -
What Is a Person-Centred Fire Risk Assessment?
Some residents require additional fire safety measures beyond those identified in a standard Fire Risk Assessment. This guide explains what a Person-Centred Fire Risk Assessment is, when it may be appropriate, and how it helps organisations manage individual fire risks while supporting compliance.
Read More about What Is a Person-Centred Fire Risk Assessment? -
How Often Should Fire Alarms Be Tested?
Routine fire alarm testing is an important part of fire safety compliance. This guide explains testing frequencies, legal responsibilities, record-keeping, and the role of BS 5839 in maintaining compliant fire alarm systems.
Read More about How Often Should Fire Alarms Be Tested?
Speak to the Osterna Team Today
Call us now or complete the form and we’ll get back to you promptly.
Get in Touch Today
✓ No obligation quote
✓ Fully accredited assessors