What Buildings Does the Building Safety Act 2022 Apply To?
13 Nov 2026 | By Ron Fellowes MIFSM, GIFireE, CertNCRQ
The Building Safety Act does not apply the same requirements to every building. This guide explains the scope of the Act, the higher-risk building definition, key height thresholds and how requirements differ between occupation, construction and other parts of the legislation.
The Building Safety Act 2022 introduced wide-ranging changes to building safety in England, but not every requirement applies to every building. Some provisions affect the wider built environment, while the most stringent occupation requirements apply specifically to higher-risk buildings.
This article explains the scope of the Building Safety Act, which buildings fall within the higher-risk regime, and when other Building Safety Act requirements may apply.
Does the Building Safety Act 2022 Apply to All Buildings?
The Building Safety Act 2022 does not impose the same requirements on every building.
Which requirements apply depends on factors such as:
- Building height and number of storeys
- How the building is used
- Whether it contains residential units
- Whether it is occupied or under construction
- The type of building work being carried out
- Ownership and repairing responsibilities
The Act also covers different areas, including building control, building regulations, higher-risk buildings and protections relating to certain historical building safety defects.
A residential block below 18 metres, for example, may fall outside the occupied higher-risk building regime but still be affected by other provisions of the Act.
Landlords, building owners and managing agents should identify which requirements apply to each building rather than treating the Act as a single set of rules for all properties.
Which Building Safety Requirements Apply to Your Building?
Different building safety requirements apply depending on a property’s height, number of storeys, use and legal status. The table below summarises the main thresholds for residential buildings in England.
| Building type or threshold | Legislation | What it means |
| Multi-occupied residential buildings with common parts | Regulatory Reform (Fire Safety) Order 2005 | Fire safety duties apply to the relevant common parts, structure, external walls and flat entrance doors. Responsible Persons must assess fire risks and maintain appropriate precautions. |
| Residential buildings with storeys over 11 metres | Fire Safety (England) Regulations 2022 | Additional duties include quarterly checks of communal fire doors and annual checks of flat entrance doors, using best endeavours for the latter. |
| At least 11 metres or five storeys, with at least two dwellings | Building Safety Act 2022 – relevant buildings | Certain leaseholder protections relating to historical building safety defects may apply, subject to the statutory conditions and exclusions. |
| At least 18 metres or seven storeys, with at least two residential units | Building Safety Act 2022 – occupied higher-risk buildings | Additional duties include registration with the Building Safety Regulator, managing building safety risks, maintaining the golden thread, preparing safety case reports and engaging with residents, subject to the statutory criteria and exclusions. |
These thresholds are not interchangeable. A building can fall within several categories, and meeting one threshold does not automatically mean every requirement in another regime applies.
For example, a six-storey residential block measuring 12 metres may be subject to additional fire door inspection duties and fall within the definition of a relevant building for leaseholder protections, without qualifying as a higher-risk building under the occupation regime.
Building height and storeys must be assessed using the measurement rules for the relevant legislation.
What Is the Definition of a Higher-Risk Building?
Under the Building Safety Act 2022, an occupied higher-risk building (HRB) in England generally contains at least two residential units and is at least 18 metres tall or has seven or more storeys, subject to statutory exclusions.
The definition differs during design and construction, when certain hospitals and care homes are also included. Mixed-use buildings can qualify where they meet the relevant criteria.
For a detailed explanation of building types, exclusions and measurement rules, read our guide to higher-risk residential buildings.
Examples of Buildings That May Fall Within the Act
The following examples show how the requirements can differ depending on a building’s height, use and residential accommodation.
| Building example | Does the occupied HRB regime apply? | What else may apply? |
| Eight-storey block of flats with shops on the ground floor | Yes, provided it contains at least two residential units and no statutory exclusion applies. The shops do not automatically exclude it. | Fire Safety Order duties and additional requirements under the Fire Safety (England) Regulations 2022. |
| Five-storey block of flats measuring 14 metres | No, assuming the height and storey count are correctly measured. | Fire Safety Order duties, additional fire door checks and potentially the Building Safety Act’s leaseholder protections. |
| Sheltered housing scheme | Depends. Sheltered housing can qualify if it meets the height or storey threshold and contains at least two residential units. | Fire Safety Order duties and potentially additional fire door requirements, depending on the building. |
| Purpose-built student accommodation block | Depends. Student accommodation can qualify where it meets the statutory height, storey and residential-unit criteria and is not excluded. | Fire Safety Order duties and applicable building control requirements. |
| Care home | No, where the building is used entirely as a care home. | Fire Safety Order duties still apply. Care homes meeting the relevant height or storey threshold can fall within the higher-risk building regime during design and construction. |
These examples are illustrative. Building use, configuration and the statutory measurement rules must be checked before confirming whether a particular property qualifies.
What If You’re Not Sure Whether Your Building Is Higher-Risk?
If a building is close to the threshold or its classification is unclear, check the following before deciding which requirements apply:
- Confirm the building’s height and storey count. Check both against the statutory measurement rules. A building only needs to meet one of the two thresholds.
- Confirm the number of residential units. Establish whether the building contains at least two residential units and whether the occupation criteria are met.
- Check how the building is used. Mixed-use buildings, sheltered housing and student accommodation may require closer assessment.
- Review the statutory exclusions. Certain building uses are excluded from the occupied higher-risk building regime, even where the height or storey threshold is met.
- Seek advice if the classification remains unclear. Consult the government’s guidance on identifying higher-risk buildings or contact the Building Safety Regulator for guidance.
Do not assume a building falls outside the wider Building Safety Act requirements simply because it does not qualify as an occupied higher-risk building.
Need Support Assessing Fire Safety Risks Across Your Residential Portfolio?
Osterna supports housing associations, managing agents and large private landlords with Fire Risk Assessments, fire door inspections and compartmentation surveys across residential buildings.
Our services help you identify fire safety risks, prioritise remedial work and maintain the records needed to demonstrate how risks are being managed.
Does the Building Safety Act Apply to Existing and New Buildings?
Both existing and new buildings can fall within the scope of the Building Safety Act.
Existing occupied HRBs are subject to ongoing requirements covering areas such as registration, building safety risks, the Golden Thread, Safety Case Reports and resident engagement. Refurbishment or remediation work can also trigger building control requirements.
New HRBs are subject to the Building Safety Regulator‘s (BSR) building control regime during design and construction.
The building’s current status and any proposed work therefore need to be considered when establishing which requirements apply.
What Does the Building Safety Act Mean for Landlords and Managing Agents?
Landlords and managing agents need to understand both which requirements apply to a building and who holds the legal responsibility for meeting them.
An Accountable Person (AP) is an individual or organisation that meets the statutory criteria through ownership of, or qualifying legal repairing obligations for, a higher-risk building’s common parts. These include the building’s structure and exterior, subject to specified exceptions, and areas shared by residents of more than one residential unit.
A building may have more than one Accountable Person. Where this happens, a Principal Accountable Person (PAP) is identified under the statutory rules and has additional responsibilities, including registering the building with the Building Safety Regulator.
Managing agents can carry out building safety activities on behalf of landlords and other dutyholders, but managing a property does not automatically make an agent an Accountable Person.
Responsibilities may include arranging inspections, maintaining building safety information, coordinating remedial work and communicating with residents. Management agreements should clearly define who carries out each activity, while landlords and other dutyholders retain appropriate oversight of their legal responsibilities.
Housing associations can read Building Safety Act: What Housing Associations Need to Know for more detail on how these requirements affect social housing portfolios.
How Does Fire Safety Fit Into Building Safety Act Compliance?
The Building Safety Act does not replace existing fire safety responsibilities. Landlords, building owners and managing agents still need to comply with the Regulatory Reform (Fire Safety) Order 2005 where it applies.
In residential buildings, this can require ongoing assessment, inspection and maintenance of the measures used to protect residents from fire. Depending on the building, this may include:
- Fire Risk Assessments to identify fire hazards, assess risk and determine whether existing precautions are appropriate
- Fire door inspections to identify defects that could affect the performance of fire doors
- Compartmentation surveys to assess whether walls, floors and other fire-resisting construction can restrict the spread of fire and smoke
These activities can also provide important information for organisations managing higher-risk buildings, particularly when assessing fire risks, planning remedial work and maintaining accurate building safety records.
Housing associations, landlords and managing agents should make sure findings are reviewed, prioritised and tracked through to completion rather than treating inspections as standalone compliance exercises.
Understanding the Scope of the Building Safety Act
There is no single building type or height threshold that defines the entire Building Safety Act scope.
The 18-metre or seven-storey threshold is central to the higher-risk building regime, but other provisions use different definitions. The building’s use, lifecycle stage, proposed work and legal arrangements can all affect which requirements apply.
Landlords, housing associations, building owners and managing agents should establish the applicable regime for each building rather than assuming that properties outside the HRB definition fall outside the Act altogether.
Osterna supports organisations responsible for residential buildings with Fire Risk Assessments, fire door inspections, compartmentation surveys and wider fire safety compliance.
Speak to the Osterna team about your building safety requirements.
Frequently Asked Questions
It can. A five-storey building will not qualify as a higher-risk building during occupation on storey count alone, as that threshold is seven storeys or 18 metres. However, other parts of the Building Safety Act legislation may still apply.
For example, a building at least five storeys or 11 metres high containing at least two dwellings may meet the definition of a relevant building for certain leaseholder protections, subject to the statutory criteria and exclusions.
The building safety regime continues to place greater emphasis on accountability, competence, building control and evidence that applicable safety standards have been met.
For higher-risk building work, the Building Safety Regulator has an important building control role, with clients, designers and contractors required to meet specific duties. The wider reforms introduced following the Grenfell Tower tragedy are intended to improve how fire and structural safety risks are managed throughout a building’s lifecycle.
Yes, mixed-use buildings can fall within the Building Safety Act. A building containing shops, offices or other commercial premises alongside residential accommodation can still qualify as a higher-risk building where it meets the relevant height, storey and residential-unit criteria.
The building’s overall use and configuration need to be considered rather than assuming commercial areas take it outside the regime.
An Accountable Person is an organisation or individual with specified legal responsibility for the common parts of an occupied higher-risk residential building, based on ownership or repairing obligations.
There can be more than one Accountable Person, with the Principal Accountable Person carrying additional responsibilities. These duties include managing relevant fire and structural safety risks and helping safeguard residents through effective building safety arrangements.
Related articles
-
Where Should Smoke Alarms Be Positioned?
Correct positioning of smoke alarms is essential for reliable fire detection and occupant protection. This guide explains where alarms should be installed, where they should be avoided, the legislation and Building Regulations that influence alarm positioning, and common installation mistakes.
Read More about Where Should Smoke Alarms Be Positioned? -
Fire Risk Assessment for Block Management
Fire Risk Assessments are a key part of managing fire safety in residential blocks. This guide explains who is responsible, what an assessment should cover and how managing agents and landlords should manage findings across their portfolios.
Read More about Fire Risk Assessment for Block Management -
Fire Risk Assessment for High-Rise Buildings
Fire risk assessments for high-rise residential buildings must consider evacuation arrangements, external walls, communal areas and building-specific fire hazards. Assessments should cover and how property and compliance teams can manage findings across complex residential buildings.
Read More about Fire Risk Assessment for High-Rise Buildings -
Fire Risk Assessment for Student Accommodation
Student accommodation presents specific fire safety challenges, from shared kitchens and changing occupancy to evacuation and sleeping risk. A Fire Risk Assessment should cover how universities, landlords and accommodation providers should manage the findings.
Read More about Fire Risk Assessment for Student Accommodation -
How to Choose a Fire Risk Assessor
Choosing the right fire risk assessor is essential for effective fire safety management and ongoing compliance. This guide explains what makes a competent fire risk assessor, why experience and third-party certification matter, what questions to ask before appointing a provider, and how to identify a high-quality Fire Risk Assessment.
Read More about How to Choose a Fire Risk Assessor -
Smoke Vent Testing: A Compliance Guide for Responsible Persons
Smoke vent testing helps verify that Automatic Opening Vents (AOVs) and smoke control systems remain operational throughout the life of a building. This guide explains the legal requirements, British Standards, recommended testing frequencies, Responsible Person duties, and how planned inspection and maintenance support ongoing fire safety compliance.
Read More about Smoke Vent Testing: A Compliance Guide for Responsible Persons -
Smoke Alarm Requirements for HMO Landlords
HMO smoke alarm requirements are more complex than those for standard rental properties. This guide explains how HMO fire alarm requirements differ, what landlords need to provide, and how to maintain fire safety compliance.
Read More about Smoke Alarm Requirements for HMO Landlords -
Smoke Alarm Regulations for Landlords
Smoke alarm regulations require landlords to install, test, and maintain smoke and carbon monoxide alarms in qualifying rental properties. This article explains the legal requirements, landlord responsibilities, smoke alarm testing, HMO considerations, and the differences between England and Scotland.
Read More about Smoke Alarm Regulations for Landlords -
How Often Should Fire Extinguishers Be Inspected?
Routine fire extinguisher inspections help identify defects before they affect emergency response. This guide explains inspection frequencies, responsibilities, what to check, and how inspections support fire safety compliance.
Read More about How Often Should Fire Extinguishers Be Inspected? -
Fire Extinguisher Maintenance Explained: Inspection, Testing and Servicing
Fire extinguishers require more than annual servicing to remain effective in an emergency. This guide explains fire extinguisher maintenance requirements, including routine inspections, professional servicing, testing, legal responsibilities, and the role of BS 5306 in supporting fire safety compliance.
Read More about Fire Extinguisher Maintenance Explained: Inspection, Testing and Servicing
Speak to the Osterna Team Today
Call us now or complete the form and we’ll get back to you promptly.
Get in Touch Today
✓ No obligation quote
✓ Fully accredited assessors