What Is a Suitable and Sufficient Fire Risk Assessment?
10 Nov 2026 | By Ron Fellowes MIFSM, GIFireE, CertNCRQ
A suitable and sufficient Fire Risk Assessment should provide more than evidence of compliance. This guide explains the legal standard, what a high-quality assessment should include, how to recognise common shortcomings, and the responsibilities of the Responsible Person.
A suitable and sufficient Fire Risk Assessment identifies significant fire risks in a specific building, considers who could be harmed, evaluates existing fire safety precautions, and provides clear, proportionate recommendations to address identified risks.
An incomplete or generic assessment can overlook serious fire hazards, putting residents and building users at risk. It can also leave Responsible Persons exposed to enforcement action if they do not adequately meet their legal duties.
Under the Regulatory Reform (Fire Safety) Order 2005, Responsible Persons must ensure their Fire Risk Assessment is suitable and sufficient for the premises and the risks involved.
What Does “Suitable and Sufficient” Mean?
The term “suitable and sufficient” appears in Article 9(1) of the Regulatory Reform (Fire Safety) Order 2005. It requires the Responsible Person to assess the fire risks to people in the building and identify the precautions needed to protect them.
Although the legislation does not prescribe a single assessment method, the assessment must be detailed enough to identify significant risks and recommend appropriate action. A generic checklist that fails to consider the building’s construction, occupancy, or fire safety arrangements may not meet this requirement.
The Five Steps of a Suitable and Sufficient Fire Risk Assessment
Government guidance for sleeping accommodation sets out five key steps. The guidance for purpose-built blocks of flats also recognises this approach, although the assessment must reflect the building’s specific circumstances.
- Identify fire hazards: Examine potential ignition sources, combustible materials, and other factors that could cause a fire.
- Identify people at risk: Consider residents, visitors, contractors, and anyone who may need assistance in an emergency.
- Evaluate and reduce risks: Assess existing precautions, including fire doors, compartmentation, escape routes, and fire detection systems.
- Record findings and plan action: Document the assessment, identify necessary improvements, and establish appropriate fire safety arrangements.
- Review the assessment: Keep the findings up to date and reassess risks following significant changes to the building or its use.
These steps help establish whether the assessment has properly considered the building’s risks and provides a practical basis for managing them.
Do Fire Risk Assessments Have to Follow British Standards?
BS 9792:2025 provides a recognised code of practice for fire risk assessments in housing, including blocks of flats and HMOs. It replaced PAS 79-2:2020 and provides guidance on risk assessment and documentation.
PAS 79-1:2020 provides a corresponding methodology for premises other than housing.
These standards represent recognised good practice, but they are not legislation. The legal requirement is to produce a suitable and sufficient assessment under the Fire Safety Order, regardless of the methodology used.
Must a Suitable and Sufficient Fire Risk Assessment Be Recorded?
Yes. Changes introduced by Section 156 of the Building Safety Act 2022 require Responsible Persons in England to record their Fire Risk Assessment in full, regardless of how many people they employ.
This includes the assessment findings, identified risks, and the measures taken or planned to address them. The previous requirement to record only significant findings in specified circumstances no longer applies.
The assessment must also be reviewed regularly and updated when significant changes affect the building’s fire safety risks.
Why Does a Suitable and Sufficient Fire Risk Assessment Matter?
A Fire Risk Assessment often forms the foundation of fire safety management across a building or residential portfolio. If it is not suitable and sufficient, significant risks may be overlooked, and Responsible Persons may struggle to manage fire safety effectively.
It Supports Better Decision-Making
Responsible Persons rely on the assessment to understand the building’s fire safety risks and decide what action to take.
A suitable and sufficient Fire Risk Assessment should clearly explain the significance of each finding, prioritise recommendations according to risk, and provide enough information to support informed decision-making.
It Helps Protect People and Property
An incomplete or poorly prepared assessment may fail to identify significant fire safety risks or recommend appropriate control measures.
A suitable and sufficient Fire Risk Assessment helps organisations identify the measures needed to reduce the risk of fire, limit fire and smoke spread, and protect residents, visitors, employees, contractors, and others who may be affected.
It Supports Fire Safety Compliance
The Fire Risk Assessment provides evidence that the Responsible Person has identified, assessed, and managed fire safety risks appropriately.
A poor-quality assessment can make it more difficult to prioritise remedial works, demonstrate compliance, or show that appropriate fire safety measures have been considered.
Need a Suitable and Sufficient Fire Risk Assessment?
Osterna supports housing associations, managing agents, local authorities, freeholders, employers, and large private landlords with professionally delivered Fire Risk Assessments and wider fire safety compliance services across the UK.
What Should a Suitable and Sufficient Fire Risk Assessment Include?
A suitable and sufficient Fire Risk Assessment should provide a clear, building-specific record of the fire safety risks identified, the measures already in place, and the actions needed to reduce risk.
Building-Specific Fire Safety Risks
The assessment should identify the significant fire hazards within the building and explain how they could affect occupants.
This should include consideration of the building’s layout, construction, occupancy, means of escape, fire doors, compartmentation, fire detection and alarm systems, emergency lighting, and other relevant fire safety measures.
People Who May Be at Risk
The assessment should identify the people who may be affected by a fire and consider whether any occupants require additional protection.
Depending on the building, this may include residents, visitors, contractors, employees, and others who use the premises. Where appropriate, the assessment should also consider people who may have difficulty evacuating independently.
In some residential settings, this may involve person-centred Fire Risk Assessments (PCFRAs) or other arrangements to help manage individual fire safety needs.
Findings and Recommendations
A suitable and sufficient Fire Risk Assessment should clearly explain:
- The significant findings
- Existing fire safety measures
- Deficiencies that require attention
- Recommendations prioritised according to risk
- Any limitations affecting the assessment
- Further investigations where necessary
Recommendations should be proportionate to the level of risk. A suitable and sufficient Fire Risk Assessment should not recommend unnecessary work where existing fire safety measures already provide an appropriate level of protection.
Every Fire Risk Assessment has limitations. Where parts of the building cannot be inspected, access is restricted, or specialist investigations are required, clearly record these limitations, along with any recommendations for further investigation.
This helps Responsible Persons understand what has and has not been assessed, and whether additional surveys or inspections are needed.
A Practical Action Plan
The assessment should provide a clear action plan that explains the next steps following the Fire Risk Assessment. This should enable the Responsible Person to prioritise remedial works, allocate responsibilities, monitor progress, and verify that identified risks have been addressed.
Responsible Persons should complete the assessment with a clear understanding of the building’s current fire safety position, the actions requiring attention, and how to manage those recommendations through to completion.
Read What Does a Fire Risk Assessment Include? for a detailed explanation of the information and recommendations a Fire Risk Assessment should contain.
How Does the Building Affect the Assessment?
No two buildings present exactly the same fire safety risks. A suitable and sufficient Fire Risk Assessment should reflect the specific characteristics of the premises rather than relying on generic assumptions or standard recommendations.
Factors that may influence the assessment include:
- Building height and layout
- Construction type
- Number and profile of occupants
- Means of escape
- Fire detection and alarm systems
- Fire doors and compartmentation
- Smoke control systems
- Building management arrangements
For example, a small office, a converted HMO, a purpose-built block of flats, and a high-rise residential building all present different fire safety challenges and may require different approaches to managing risk.
Assessments that rely on generic wording or standard recommendations without considering the individual building may not provide Responsible Persons with enough information to manage fire safety effectively.
What Are the Signs That a Fire Risk Assessment Is Not Suitable and Sufficient?
A suitable and sufficient Fire Risk Assessment should give Responsible Persons confidence that significant fire safety risks have been identified and clearly explained. If the report creates uncertainty or leaves important questions unanswered, it may not provide an adequate basis for managing fire safety.
Generic Rather Than Building-Specific
Every building presents different fire safety risks. Reports that rely on standard wording or recommendations without reflecting the building’s layout, construction, occupancy, or management may not meet the required standard.
Important Risks Are Missing or Poorly Explained
A Fire Risk Assessment should explain each finding’s significance and why action is required. Missing information about fire doors, compartmentation, means of escape, fire detection systems, or other key fire safety measures may indicate an incomplete assessment.
Recommendations Are Difficult to Act Upon
Recommendations should be proportionate, prioritised, and supported by sufficient information to allow the Responsible Person to plan remedial works.
Reports that provide vague recommendations, treat every finding as equally urgent, or include no clear action plan often make it difficult to decide what should happen next.
The Assessment Has Not Been Reviewed
A Fire Risk Assessment reflects the building at the time it was completed. Significant alterations, changes in occupancy, completed remedial works, or a fire incident may mean the assessment no longer reflects the building’s current fire safety risks.
For more information on the events that may require a Fire Risk Assessment to be reviewed or repeated, read How Often Should a Fire Risk Assessment Be Carried Out?
The Assessor’s Competence Cannot Be Demonstrated
The quality of a Fire Risk Assessment depends on the competence of the person conducting it. If the assessor cannot demonstrate appropriate qualifications, relevant experience, or third-party certification, Responsible Persons should consider whether the assessment provides a reliable basis for managing fire safety.
Where there are concerns about the quality of an assessment, it may be appropriate to commission a new assessment from a competent, independently certificated provider. Read our article, How to Choose a Fire Risk Assessor, to learn what qualifications, experience, and third-party certification to look for when appointing an assessor.
Who Decides Whether a Fire Risk Assessment Is Suitable and Sufficient?
The Responsible Person is legally responsible for making sure a Fire Risk Assessment is suitable and sufficient. Although a competent fire risk assessor may carry out the assessment, the Responsible Person must be satisfied that it adequately identifies the building’s fire risks and recommends appropriate precautions.
The fire and rescue authority may examine the assessment during an inspection to determine whether it meets the requirements of the Regulatory Reform (Fire Safety) Order 2005. If the assessment is inadequate, the authority can take enforcement action requiring the business to address the deficiencies.
If a case reaches prosecution, the court ultimately decides whether the relevant legal requirements have been breached. An inadequate Fire Risk Assessment may form part of the evidence supporting a prosecution, depending on the circumstances.
Ensure Your Fire Risk Assessment Meets the Required Standard
Not all Fire Risk Assessments provide the same level of quality or practical value. A suitable and sufficient assessment should reflect the specific building, identify significant fire safety risks, and provide clear, proportionate recommendations that support effective fire safety management.
If you would like advice on whether your current Fire Risk Assessment meets the required standard, or need to commission a new assessment, speak to the Osterna team.
As a trusted, BAFE SP205-accredited provider, we support housing associations, managing agents, local authorities, and large private landlords across the UK with professionally delivered Fire Risk Assessments and wider fire safety compliance services.
Frequently Asked Questions
The Responsible Person is legally responsible for ensuring a suitable and sufficient Fire Risk Assessment is carried out. Although a competent fire risk assessor may complete the assessment, the Responsible Person remains responsible for commissioning it, reviewing its findings, and managing any resulting actions.
There is no mandatory Fire Risk Assessment template under the Regulatory Reform (Fire Safety) Order 2005. However, government guidance and recognised standards, including BS 9792:2025 for housing and PAS 79-1:2020 for non-housing premises, provide good practice for carrying out and recording assessments. Regardless of the format used, the assessment must be suitable and sufficient for the building and its fire risks.
Yes. A Fire Risk Assessment reflects the building at the time it was completed. Significant alterations, changes in occupancy, completed remedial works, changes to fire safety arrangements, or a fire incident may all mean the assessment should be reviewed to ensure it remains suitable and sufficient.
No. A suitable and sufficient Fire Risk Assessment is an important part of fire safety compliance, but it does not guarantee compliance on its own. The Responsible Person must also implement appropriate fire safety measures, complete remedial works where required, and review the assessment regularly.
An inadequate Fire Risk Assessment can lead to enforcement action under the Regulatory Reform (Fire Safety) Order 2005. The fire and rescue authority may require the Responsible Person to address deficiencies and arrange a more thorough assessment. Serious breaches may result in prosecution, particularly where failures place people at risk of death or serious injury.
No. A suitable and sufficient Fire Risk Assessment should reflect the specific building, its occupants, and the fire safety risks present. The scope and focus will vary depending on factors such as the building’s construction, height, occupancy, and fire safety arrangements.
Related articles
-
Emergency Lighting Regulations: A Guide for UK Responsible Persons
Emergency lighting helps occupants evacuate safely when normal lighting fails, but many Responsible Persons are unsure which regulations apply. This guide explains UK emergency lighting legislation, the role of BS 5266, where emergency lighting is required, and how it supports wider fire safety compliance.
Read More about Emergency Lighting Regulations: A Guide for UK Responsible Persons -
Dry Riser Testing Regulations: What Building Owners Need to Know
Dry riser testing is essential for maintaining reliable firefighting systems within residential and commercial buildings. This guide explains the legislation and British Standards governing dry riser inspection and pressure testing, recommended testing frequencies, Responsible Person responsibilities, common defects, and how planned maintenance supports ongoing fire safety compliance.
Read More about Dry Riser Testing Regulations: What Building Owners Need to Know -
How Often Should Emergency Lighting Be Tested?
Emergency lighting testing helps ensure escape routes remain illuminated during a fire or power failure. This guide explains the monthly and annual testing routine required under BS 5266, who’s responsible, and what the law expects from Responsible Persons.
Read More about How Often Should Emergency Lighting Be Tested? -
How Much Does Fire Extinguisher Inspection Cost?
Fire extinguisher inspection costs vary depending on the number of extinguishers, building complexity, servicing requirements, and reporting needs. This guide explains the factors that influence pricing, what’s included within a professional inspection service, and how to obtain an accurate quotation.
Read More about How Much Does Fire Extinguisher Inspection Cost? -
Fire Extinguisher Inspection Checklist: What’s Included
A fire extinguisher inspection helps ensure portable firefighting equipment remains accessible, operational, and ready for use. This guide explains what a fire extinguisher inspection is, what’s included in a typical inspection checklist, and the key checks Responsible Persons should carry out as part of an effective fire safety maintenance programme.
Read More about Fire Extinguisher Inspection Checklist: What’s Included -
A Guide to HMO Fire Risk Assessment Requirements
Many HMO landlords understand they have fire safety responsibilities, but fewer are clear on exactly what the law requires. Misunderstanding those duties can lead to compliance issues, licensing problems, and increased risk to residents. This guide explains the fire risk assessment requirements that apply to HMOs and what landlords and managing agents need to do in practice.
Read More about A Guide to HMO Fire Risk Assessment Requirements -
A Guide to Fire Risk Assessments for Landlords
Not every landlord needs a fire risk assessment, but misunderstanding where the legal duty applies can create significant compliance risks. Discover which properties require an assessment, the legislation involved, and what landlords need to do to meet their fire safety responsibilities.
Read More about A Guide to Fire Risk Assessments for Landlords -
What Is the Difference Between a PCFRA and a PEEP?
A Person-Centred Fire Risk Assessment and a Personal Emergency Evacuation Plan are often confused, but they are designed to achieve different outcomes. This guide explains the key differences, when each is appropriate, and how they work together to support fire safety within residential buildings.
Read More about What Is the Difference Between a PCFRA and a PEEP? -
What Is a Person-Centred Fire Risk Assessment?
Some residents require additional fire safety measures beyond those identified in a standard Fire Risk Assessment. This guide explains what a Person-Centred Fire Risk Assessment is, when it may be appropriate, and how it helps organisations manage individual fire risks while supporting compliance.
Read More about What Is a Person-Centred Fire Risk Assessment? -
How Often Should Fire Alarms Be Tested?
Routine fire alarm testing is an important part of fire safety compliance. This guide explains testing frequencies, legal responsibilities, record-keeping, and the role of BS 5839 in maintaining compliant fire alarm systems.
Read More about How Often Should Fire Alarms Be Tested?
Speak to the Osterna Team Today
Call us now or complete the form and we’ll get back to you promptly.
Get in Touch Today
✓ No obligation quote
✓ Fully accredited assessors